APPENDIX C. ENVIRONMENTAL TEST DESCRIPTIONS
ANNEX 2. DYNAMIC TESTS
c.
Number of Shocks. One shock each in the positive and negative longitudinal axes.
d. Test Temperature. Temperature condition the test munitions prior to, and during
vibration testing. Stabilize all cold munitions to -46 °C (and all hot munitions to the unpackaged
SRE temperature. Naval surface launched munitions may be tested at -34 °C.
C.2-10.2 Free Flight Vibration.
Conduct free flight vibration testing in accordance with MIL-STD-810, Methods 514 or 525 as
appropriate. Tailor test levels based on measured data. Test severities should be derived in
accordance with MIL-STD-810, Method 514, Annex F.
a.
Test Configuration. Attach the munition to the vibration exciter as appropriate.
b. Test Level. The tailored test levels are typically specified as a random vibration profile
in accordance with the test severity derived in accordance with MIL-STD-810, Method 514, Annex
F.
c. Test Duration. The test duration in each axis should be adequate to address the safe
separation distance of the munitions from the launch platform.
d. Test Temperature. Test temperatures of 71 °C and -46 °C are based on anticipated
temperatures at launch. Half of the test quantity should be conducted hot and half cold. Naval
surface launched munitions may be tested at -34 °C.
C.2-16