JOTP-011
5 December 2014
APPENDIX B. TEST PROGRAM FOR SURFACE AND UNDERWATER LAUNCHED MUNITIONS
ANNEX 3. WORKED EXAMPLE OF TEST TAILORING FOR A SURFACE LAUNCHED MISSILE SYSTEM
TABLE B3-2. EXAMPLE TAILORED SEQUENTIAL ROUND ALLOCATION FOR EMPIRICAL S3 TEST PROGRAM
Munition number (Live Munitions)
Test serial
App/Annex/Para
1
2
3
4
5
6
7
8 9-11 12-13 14 15 16 17 18
19
20
21 22-24 25-26
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
c
c
c
c
c
c
c
c
c
c
ccccc
c
c
c
c
c
Common carrier vibration
C/2/1.1
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Packaged transit drop
C/2/1.2
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
a
a
a
a
a
a
a
a
aaaaa
a
a
a
a
a
Humid heat
C/1/1
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
Low temperature storage
C/1/2
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
High temperature storage
C/1/3
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
High temperature cycling
C/1/4
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
Solar radiation
C/1/5
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
Thermal shock
C/1/6
x
x
x
x
x
x
x
x
x
x
xxxxx
x
x
x
x
x
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
c
c
c
c
c
c
c
c
c
c
ccccc
c
c
c
c
c
Sea Transport Dynamics
C/2/3
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
a
a
a
a
a
a
a
a
aaaaa
a
a
a
a
a
Air Transport Dynamics - Military
C/2/4
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
a
a
a
a
a
a
a
a
aaaaa
a
a
a
a
a
Land Transport Dynamics - Military
C/2/2
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
a
a
a
a
a
a
a
a
aaaaa
a
a
a
a
a
Tactical Combat Platform Dynamics
C/2/5
h
h
h
h
h
h
h
h
h
h
ccccc
c
c
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
c
c
c
c
c
c
c
c
c
c
ccccc
c
c
c
c
c
Tactical Drop
C/2/6
h
h
h
h
h
h
c
cc
c
c
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
c
c
c
c
c
c
c
cc
c
c
c
Cargo Aircraft Rapid Decompression
C/1/12
a
a
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
Rail Impact
C/2/1.3
h
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
a
a
Rough Handling Transit Drop*
C/2/7
h
c
Level 2 Inspection (BIT, visual, NDT,
radiography)
7.3
c
c
Level 3 Inspection (Reduced BTCA)
7.4
a
a
a
aa
a
Dynamic firing tests
D/1/1
h
h
c
c
a = ambient test
Key:
c = cold conditioned test
* If munition survives the drop test determine whether to dispose of the munition or to disassemble for BTCA.
h = hot conditioned test
x = test temperature defined in test
B.3-5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business