JOTP-011
5 December 2014
APPENDIX F. FACILITIES AND INSTRUMENTATION REQUIREMENTS
TABLE F-2. MEASUREMENT TOLERANCES
DEVICES FOR MEASURING
MEASUREMENT TOLERANCE
5 percent of the value or 200 Pa, whichever is greater.
Pressure
1 percent of highest expected value
Strain
1 percent of highest expected value
Thrust (Load Cells)
1 percent of highest expected value
Heat Flux
0.05 ohms
Resistance (Low Current Circuit Tester/
Squib Tester)
Firing Pulse (Automatic Fire Control
As required for the initiation of static fire or burst tests and
System)
the automatic sequencing of the data collection systems.
Motor Ignition Events (Video)
Frame rate sufficient to record desired event.
1 percent
Time
Temperature
2 °C
Climatic Temperature Measurements
5 °C
Static Fire/Burst Temperature
Measurements
5 percent
Relative Humidity
20 W/m 2
Solar Radiation
Vibration Acceleration
See MIL-STD-810, Method 514
Acoustic Sound Pressure Level
See MIL-STD-1474
Mechanical Shock
See MIL-STD-810, Method 516
Toxic Gas (NO, NO2, NOx, CO, CO2, SO2)
2 percent of full scale
Particulates (0.5-15 microns)
2 percent of full scale
Pyrolysis products (fluoride, chloride,
2 percent of full scale
bromide, cyanide, aldehydes)
1 percent
Length
1 percent
Weight
Meteorological Conditions
2 °C
Temperature
3 percent
Relative Humidity
0.25 mm of Hg
Barometric Pressure
20 W/m2
UV Radiation
> 2 km
Potential Lightning/Severe Weather
3 km/hr
Wind
F-3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business