TABLE F-1. FACILITY REQUIREMENTS (CONTINUED)
ITEM
REQUIREMENT
Warhead Test Area
Test area must have an adequate surface safety danger zone, including
overhead air space for open field testing.
Munition Disassembly
Facility suitable for disassembly of live munitions for detailed inspection
and component level testing.
Energetic Material
Equipment suitable for the extraction of energetic material samples for
Extraction
chemical analysis.
(if required)
Chemistry Laboratory
Equipment suitable for the conduct of the chemical analysis tests set out in
(if required)
STANAG 4170, AOP-7, and paragraphs E.2.7.2 through E.2.7.6 of
Appendix E (BTCA).
Electromagnetic
Facility suitable for the generation of the specified field intensities with an
Radiation Test
adequate test volume for the test of the munition and launcher as required
by the stockpile to launch configuration.
Facility
Electrostatic Discharge
Facility suitable for the generation of the required ESD environments and
Test Facility
large enough for the munition and launcher as required by the stockpile to
launch configuration.
Lightning Test Facility
Facility capable of conducting the required lightning strike test on live
munitions.
Data
Test data shall be recorded on Digital Recorders for post-test processing.
Collection/Processing
The data processing system shall edit, display, and print out the desired
Facility
data plot for analysis and reporting purposes.
Video/Photographic
Closed circuit video is required for personnel safety to permit observation of
munition tests. Video Camera/Recording Systems having a sufficient
frame rate to record and playback desired events. High speed digital
cameras and/or UV/IR cameras may also be required.