APPENDIX H. NON-SEQUENTIAL TESTS/ASSESSMENTS
ANNEX 1. ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)
b. Direct or indirect (or both where appropriate) lightning tests shall be performed using
inert weapons with instrumented inert or live EIDs/ESADs. A minimum of 20 complete sets of
EIDs/ESADs (10 for indirect lightning strike and 10 for direct lightning strike) are required to
provide adequate data when instrumented components are not available (see Appendix B). In
addition, Nation specific requirements may necessitate direct and/or indirect lightning tests on one
complete live munition.
c. Perform the lightning strike tests using the parameters found in MIL-STD-464.
H.1-4 ELECTROMAGNETIC COMPATIBILITY (EMC).
Where appropriate EMC susceptibility tests are carried out on one complete inert weapon and
should be completed in accordance with the MIL-STD-461 and MIL-STD-464 series of tests. EMC
Source -Victim tests are carried out with an inert weapon with instrumented EIDs/ESADs. In some
cases, National Standards and Regulations may also apply.